Institute of Electrical Engineering and Electrotechnologies, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, Nadbystrzycka 38d, Lublin, Poland
Different diagnostic methods can be used to determine electrons and gas temperatures in the gliding arc plasma reactor. The electrons’ temperature has been determined by optical spectroscopy and gas temperature – by ther-movision camera. The results of the thermovision diagnostics of the plasma generated by gliding arc for different process gases and their flow rates are presented and discussed in the paper.
We process personal data collected when visiting the website. The function of obtaining information about users and their behavior is carried out by voluntarily entered information in forms and saving cookies in end devices. Data, including cookies, are used to provide services, improve the user experience and to analyze the traffic in accordance with the Privacy policy. Data are also collected and processed by Google Analytics tool (more).