PL EN
Determination of the Air Purification Efficiency when Using a Biofilter
 
Więcej
Ukryj
1
Michurinsk State Agrarian University, Internatsionalnaya Street, 101, Michurinsk, 393760, Russia
 
 
Data publikacji: 01-12-2019
 
 
Autor do korespondencji
Ivan Krivolapov   

Michurinsk State Agrarian University, Internatsionalnaya Street, 101, Michurinsk, 393760, Russia
 
 
J. Ecol. Eng. 2019; 20(11):232-239
 
SŁOWA KLUCZOWE
DZIEDZINY
 
STRESZCZENIE
The work presents the results of experimental studies on the air purification efficiency after accelerated composting of a mixture of cattle manure and straw in a chamber-type biofermenter. The operation of an experimental plant that simulates this process is described. A process optimization criterion has been established, its values have been determined for each of the pollutants – ammonia and hydrogen sulfide. The maximum purification efficiency for ammonia is 92%, achieved at 47% moisture content of the filtering material and 58% compost weight parts at 30°C. For hydrogen sulfide, the maximum purification efficiency is 95%, achieved at 50% moisture content of the filtering material and 52% compost weight part at 28°C
Journals System - logo
Scroll to top